Modbus Address: 100 Gerätename: GreenController 140/30 |
| MB-Variable |
MB Addresse |
MB Länge |
Lesen |
Schreiben |
Wert |
Einheit |
Beschreibung |
| DEVICE_TYPE_ID |
0 |
1 |
ja |
nein |
1025 |
|
Hardware ID |
| DEVICE_TYPE_NAME |
0 |
1 |
ja |
nein |
GreenController 140/30 |
|
Gerätetyp |
| FW_VERSION |
1 |
1 |
ja |
nein |
1.10 |
|
Firmware Version |
| FW_SUB_VERSION |
640 |
1 |
ja |
nein |
11 |
|
Firmware Subversion |
| ID_SERNO |
2 |
6 |
ja |
nein |
32 59 35 31 30 34 06 1a 00 04 00 00 |
|
Seriennummer |
| BATT_TYPE |
10 |
1 |
ja |
ja |
2 |
|
Battrie Zellentyp |
| BATT_TYPE_TXT |
10 |
1 |
ja |
ja |
LIFEYPO4 |
|
Batterie Zellentyp |
| BATT_CELL_CURRENT_LIMIT |
10 |
1 |
ja |
ja |
1 |
|
Strombegrenzung in Kapazität / X |
| BATT_EQUALIZE_INTERVAL |
11 |
1 |
ja |
nein |
0 |
Tage |
Equalize Intervall |
| BATT_ABSORPTION_TIME |
12 |
1 |
ja |
ja |
5 |
Minuten |
Absorptionszeit |
| BATT_FLOAT_EXIT_TIME |
13 |
1 |
ja |
ja |
45 |
Minuten |
Float Exit Zeit |
| BATT_EQUALIZE_TIME |
14 |
1 |
ja |
ja |
0 |
Minuten |
Equalize Zeit |
| CELL_ABSORPTION_VOLTAGE |
15 |
2 |
ja |
ja |
3.5 |
V |
Zelle Absorptionsspannung |
| CELL_ABSORPTION_EXIT_VOLTAGE |
17 |
2 |
ja |
ja |
3.44 |
V |
Zelle Absorptions Abbruch Spannung |
| CELL_FLOAT_VOLTAGE |
19 |
2 |
ja |
ja |
3.45 |
V |
Zelle Float Spannung |
| CELL_FLOAT_EXIT_VOLTAGE |
21 |
2 |
ja |
ja |
3.38 |
V |
Zelle Float Abbruch Spannung |
| CELL_EQUALIZE_VOLTAGE |
23 |
2 |
ja |
ja |
3.7 |
V |
Zelle Equalize Spannung |
| CELL_CUT_OFF_VOLTAGE |
25 |
2 |
ja |
ja |
3 |
V |
Zelle Abschaltspannung |
| CELL_CUT_OFF_RECOVERY_VOLTAGE |
27 |
2 |
ja |
ja |
3.2 |
V |
Zelle Wiedereinschalt Spannung |
| CELL_TEMP_COEFFICIENT |
29 |
2 |
ja |
ja |
-0 |
V |
Zelle Temperaturkoeffizient |
| BATT_CEF |
31 |
1 |
ja |
ja |
94 |
% |
Ladewirkungsgrad |
| BATT_PEUKERT |
31 |
1 |
ja |
ja |
100 |
|
Peukert Faktor |
| BATT_CELL_TYPE |
33 |
1 |
ja |
ja |
7 |
|
Zellentyp (laut Tabelle) |
| BATT_CELL_TYPE_TXT |
33 |
1 |
ja |
ja |
Lithium LiFeYPo4 (3.7V Absorption) |
|
Zellentyp (laut Tabelle) |
| BATT_CELLS_COUNT |
33 |
1 |
ja |
ja |
8 |
|
Anzahl Zellen |
| BATT_CAPACITY |
34 |
1 |
ja |
ja |
300 |
Ah |
Batteriekapazität |
| BATT_CUT_OFF_DELAY |
35 |
1 |
ja |
ja |
5 |
Minuten |
Verzögerung der Lastabschaltung nach LVP |
| START_EQUALIZE |
35 |
1 |
ja |
ja |
0 |
|
Equalize nach nächster Vollladung 0-nein 1-ja |
| MPP_MODE |
37 |
1 |
ja |
ja |
3 |
|
MPP Modus |
| MPP_MODE_TXT |
37 |
1 |
ja |
nein |
ECS Combined MPP |
|
MPP Modus |
| MPP_VOLTAGE |
37 |
1 |
ja |
ja |
65 |
V |
MPP Spannung wenn "CONSTANT VOLTAGE"(1) eingestellt ist (MPP_MODE() bzw. MPP_MODE_TXT()) |
| LB_SLAVE_ADDRESS |
38 |
1 |
ja |
ja |
100 |
|
Modbus Geräteadresse |
| LB_MODE |
38 |
1 |
ja |
ja |
1 |
|
Modbus-Mode (0-Slave 1-Master) |
| LB_MODE_TXT |
38 |
1 |
ja |
nein |
MASTER MODE |
|
Modbus-Mode (Master/Slave) |
| LB_BAUDRATE_MODE |
39 |
1 |
ja |
ja |
2 |
|
Baudrate 0-9600 1-14400 2-19200 3-28800 4-38400 5-57600 6-76800 7-115200 |
| LB_BAUDRATE_MODE_TXT |
39 |
1 |
ja |
ja |
19200 |
|
Baudrate |
| LB_PARITY_MODE |
39 |
1 |
ja |
ja |
1 |
|
Parität 0-ohne 1-gerade 2-ungerade |
| LB_PARITY_MODE_TXT |
39 |
1 |
ja |
nein |
gerade (even) |
|
Parität |
| LB_STOPBIT_MODE |
40 |
1 |
ja |
ja |
1 |
|
Anzahl Stopbits |
| LB_NUMBER_OF_GC |
40 |
1 |
ja |
ja |
1 |
|
Anzahl GreenController |
| SL_MIDNIGHT_DETECTION |
43 |
1 |
ja |
ja |
0 |
|
streetlight: midnight detection as number |
| SL_MIDNIGHT_DETECTION_TXT |
43 |
1 |
ja |
nein |
off |
|
streetlight: midnight detection as text |
| SL_LED_POWER_FULL |
43 |
1 |
ja |
ja |
200 |
|
streetlight: set PWM on maximum brightness |
| SL_LED_POWER_RED |
44 |
1 |
ja |
ja |
100 |
|
streetlight: PWM on maximum brightness |
| SL_VOLT_ON |
44 |
1 |
ja |
ja |
5 |
V |
streetlight: switch on voltage |
| SL_VOLT_OFF |
45 |
1 |
ja |
ja |
10 |
V |
streetlight: switch off voltage |
| SL_TIME_RED_START_HOURS |
45 |
1 |
ja |
ja |
22 |
|
streetlight: hour in with switched to reduced brightness; only for "Half Day Mode" |
| SL_TIME_RED_STOP_HOURS |
46 |
1 |
ja |
ja |
5 |
|
streetlight: hour in with switched to maximum brightness; only for "Half Day Mode" |
| SL_TIME_RED_START_MINUTES |
46 |
1 |
ja |
ja |
0 |
|
streetlight: minute in with switched to reduced brightness; only for "Half Day Mode" |
| SL_TIME_RED_STOP_MINUTES |
47 |
1 |
ja |
ja |
0 |
|
streetlight: minute in with switched to maximum brightness; only for "Half Day Mode" |
| SL_DIM_SPEED |
47 |
1 |
ja |
ja |
1 |
|
streetlight: dimming speed |
| SL_LED_TIME_MOTION |
48 |
1 |
ja |
ja |
60 |
|
streetlight: time for maximum brightness after motion detection |
| SL_MODE |
49 |
1 |
ja |
ja |
0 |
|
streetlight: lightning mode as number |
| SL_MODE_TXT |
49 |
1 |
ja |
nein |
off |
|
streetlight: lightning mode as text |
| GSM_MODULE_ENABLED |
51 |
1 |
ja |
ja |
0 |
|
GSM modul enabled as number |
| GSM_MODULE_ENABLED_TXT |
51 |
1 |
ja |
nein |
off |
|
GSM modul enabled as text |
| GSM_HEARTBEAT_INTERVAL_TIME |
52 |
1 |
ja |
ja |
0 |
Sekunden |
GSM heartbeat interval |
| APN_NAME |
60 |
25 |
ja |
ja |
internet.eplus.de |
|
GSM access point name |
| APN_USER |
85 |
25 |
ja |
ja |
eplus |
|
GSM accress point username |
| APN_PW |
110 |
25 |
ja |
ja |
gprs |
|
GSM access point password |
| GSM_SERVER_NAME |
135 |
25 |
ja |
ja |
www.green-control.de |
|
GSM server name |
| GSM_SERVER_PORT |
160 |
25 |
ja |
ja |
9756 |
|
GSM server port |
| OUT1_EXT_OUTPUT_MODE |
185 |
1 |
ja |
ja |
10 |
|
Externer Ausgang 1 Ausgangsmode |
| OUT1_EXT_OUTPUT_MODE_TXT |
185 |
1 |
ja |
nein |
SOC |
|
Externer Ausgang 1 Ausgangsmode |
| OUT1_INVERTED |
185 |
1 |
ja |
ja |
1 |
|
Externer Ausgang 1 invertiert/nicht invertiert |
| OUT1_OUTPUTINVERTED_TXT |
185 |
1 |
ja |
nein |
invertiert |
|
Externer Ausgang 1 invertiert/nicht invertiert |
| OUT1_V_HIGH |
186 |
1 |
ja |
ja |
80 |
V, %, °C |
external output1: switch-on threshold in V, % or °C (depending on the selected output mode) |
| OUT1_V_LOW |
187 |
1 |
ja |
ja |
70 |
V, %, °C |
external output1: switch-off threshold in V, % or °C (depending on the selected output mode) |
| OUT1_HOLD_TIME |
188 |
1 |
ja |
ja |
5 |
Minuten |
external output1: hold time |
| OUT2_EXT_OUTPUT_MODE |
189 |
1 |
ja |
ja |
10 |
|
Externer Ausgang 2 Ausgangsmode |
| OUT2_EXT_OUTPUT_MODE_TXT |
189 |
1 |
ja |
nein |
SOC |
|
Externer Ausgang 2 Ausgangsmode |
| OUT2_INVERTED |
189 |
1 |
ja |
ja |
0 |
|
Externer Ausgang 2 invertiert/nicht invertiert |
| OUT2_OUTPUTINVERTED_TXT |
189 |
1 |
ja |
nein |
nicht invertiert |
|
Externer Ausgang 2 invertiert/nicht invertiert |
| OUT2_V_HIGH |
190 |
1 |
ja |
ja |
99 |
V, %, °C |
external output2: switch-on threshold in V, % or °C (depending on the selected output mode) |
| OUT2_V_LOW |
191 |
1 |
ja |
ja |
87 |
V, %, °C |
external output2: switch-off threshold in V, % or °C (depending on the selected output mode) |
| OUT2_HOLD_TIME |
192 |
1 |
ja |
ja |
5 |
Minuten |
external output2: hold time |
| OUT3_EXT_OUTPUT_MODE |
193 |
1 |
ja |
ja |
7 |
|
Externer Ausgang 3 Ausgangsmode |
| OUT3_EXT_OUTPUT_MODE_TXT |
193 |
1 |
ja |
nein |
CHARGER CONTROL |
|
Externer Ausgang 3 Ausgangsmode |
| OUT3_INVERTED |
193 |
1 |
ja |
ja |
0 |
|
Externer Ausgang 3 invertiert/nicht invertiert |
| OUT3_OUTPUTINVERTED_TXT |
193 |
1 |
ja |
nein |
nicht invertiert |
|
Externer Ausgang 3 invertiert/nicht invertiert |
| OUT3_V_HIGH |
194 |
1 |
ja |
ja |
28 |
V, %, °C |
external output3: switch-on threshold in V, % or °C (depending on the selected output mode) |
| OUT3_V_LOW |
195 |
1 |
ja |
ja |
24 |
V, %, °C |
external output3: switch-off threshold in V, % or °C (depending on the selected output mode) |
| OUT3_HOLD_TIME |
196 |
1 |
ja |
ja |
5 |
Minuten |
external output3: hold time |
| OUT4_EXT_OUTPUT_MODE |
197 |
1 |
ja |
ja |
4 |
|
Externer Ausgang 4 Ausgangsmode |
| OUT4_EXT_OUTPUT_MODE_TXT |
197 |
1 |
ja |
nein |
CHARGER STATE |
|
Externer Ausgang 4 Ausgangsmode |
| OUT4_INVERTED |
197 |
1 |
ja |
ja |
0 |
|
Externer Ausgang 4 invertiert/nicht invertiert |
| OUT4_OUTPUTINVERTED_TXT |
197 |
1 |
ja |
nein |
nicht invertiert |
|
Externer Ausgang 4 invertiert/nicht invertiert |
| OUT4_V_HIGH |
198 |
1 |
ja |
ja |
28 |
V, %, °C |
external output4: switch-on threshold in V, % or °C (depending on the selected output mode) |
| OUT4_V_LOW |
199 |
1 |
ja |
ja |
24 |
V, %, °C |
external output4: switch-off threshold in V, % or °C (depending on the selected output mode) |
| OUT4_HOLD_TIME |
200 |
1 |
ja |
ja |
5 |
Minuten |
external output4: hold time |
| INPUT1_EXT_INPUT_MODE |
201 |
1 |
ja |
ja |
7 |
|
external input1: input mode as number |
| INPUT1_EXT_INPUT_MODE_TXT |
201 |
1 |
ja |
nein |
Ausgangsstromsensor 200A |
|
external input1: input mode as text |
| INPUT1_INVERTED |
201 |
1 |
ja |
ja |
0 |
|
external input1: inverted as number |
| INPUT1_INPUTINVERTED_TXT |
201 |
1 |
ja |
nein |
nicht invertiert |
|
external input1: inverted as text |
| INPUT1_I_LIM_MIN |
202 |
1 |
ja |
ja |
1 |
A |
external input1: external current lower limit |
| INPUT1_V_HIGH |
203 |
1 |
ja |
ja |
4 |
V |
external input1: switch-on threshold |
| INPUT1_V_LOW |
204 |
1 |
ja |
ja |
1 |
V |
external input1: switch-off threshold |
| INPUT2_EXT_INPUT_MODE |
205 |
1 |
ja |
ja |
0 |
|
external input2: input mode as number |
| INPUT2_EXT_INPUT_MODE_TXT |
205 |
1 |
ja |
nein |
disabled |
|
external input2: input mode as text |
| INPUT2_INVERTED |
205 |
1 |
ja |
ja |
0 |
|
external input2: inverted as number |
| INPUT2_INPUTINVERTED_TXT |
205 |
1 |
ja |
nein |
nicht invertiert |
|
external input2: inverted as text |
| INPUT2_I_LIM_MIN |
206 |
1 |
ja |
ja |
1 |
A |
external input2: external current lower limit |
| INPUT2_V_HIGH |
207 |
1 |
ja |
ja |
4 |
V |
external input2: switch-on threshold |
| INPUT2_V_LOW |
208 |
1 |
ja |
ja |
1 |
V |
external input2: switch-off threshold |
| INPUT3_EXT_INPUT_MODE |
209 |
1 |
ja |
ja |
0 |
|
external input3: input mode as number |
| INPUT3_EXT_INPUT_MODE_TXT |
209 |
1 |
ja |
nein |
disabled |
|
external input2: input mode as text |
| INPUT3_INVERTED |
209 |
1 |
ja |
ja |
0 |
|
external input3: inverted as number |
| INPUT3_INPUTINVERTED_TXT |
209 |
1 |
ja |
nein |
nicht invertiert |
|
external input3: inverted as text |
| INPUT3_I_LIM_MIN |
210 |
1 |
ja |
ja |
1 |
A |
external input3: external current lower limit |
| INPUT3_V_HIGH |
211 |
1 |
ja |
ja |
4 |
V |
external input3: switch-on threshold |
| INPUT3_V_LOW |
212 |
1 |
ja |
ja |
1 |
V |
external input3: switch-off threshold |
| INPUT4_EXT_INPUT_MODE |
213 |
1 |
ja |
ja |
0 |
|
external input4: input mode as number |
| INPUT4_EXT_INPUT_MODE_TXT |
213 |
1 |
ja |
nein |
disabled |
|
external input2: input mode as text |
| INPUT4_INVERTED |
213 |
1 |
ja |
ja |
0 |
|
external input4: inverted as number |
| INPUT4_INPUTINVERTED_TXT |
213 |
1 |
ja |
nein |
nicht invertiert |
|
external input4: inverted as text |
| INPUT4_I_LIM_MIN |
214 |
1 |
ja |
ja |
1 |
A |
external input4: external current lower limit |
| INPUT4_V_HIGH |
215 |
1 |
ja |
ja |
4 |
V |
external input4: switch-on threshold |
| INPUT4_V_LOW |
216 |
1 |
ja |
ja |
1 |
V |
external input4: switch-off threshold |
| SMS_ALARM_LEVEL |
225 |
1 |
ja |
ja |
0 |
|
SMS alarm level |
| PHONE_NUMBER |
227 |
18 |
ja |
ja |
0049123456 |
|
phone numer for alarm messages |
| CMD |
245 |
1 |
nein |
ja |
|
|
Set CMD Modbus function 245; look at the documentation |
| SET_OUTPUT1 |
245 |
1 |
nein |
ja |
|
|
Ausgang1 auf LOW; HIGH setzen wenn er nicht im Dimming-Mode ist |
| SET_OUTPUT2 |
245 |
1 |
nein |
ja |
|
|
Ausgang2 auf LOW; HIGH setzen wenn er nicht im Dimming-Mode ist |
| SET_OUTPUT3 |
245 |
1 |
nein |
ja |
|
|
Ausgang3 auf LOW; HIGH setzen |
| SET_OUTPUT4 |
245 |
1 |
nein |
ja |
|
|
Ausgang4 auf LOW; HIGH setzen |
| SET_LOAD_OUTPUT |
245 |
1 |
nein |
ja |
|
|
Lastausgang ein/aus/user |
| RESET |
245 |
1 |
nein |
ja |
|
|
GC Reset |
| DEBUG_MODE |
246 |
1 |
ja |
ja |
0 |
|
debug mode as number |
| DEBUG_MODE_TXT |
246 |
1 |
ja |
nein |
off |
|
debug mode as text |
| LOAD_OUTPUT_MODE |
247 |
1 |
ja |
ja |
0 |
|
load output reconnect mode as number |
| LOAD_OUTPUT_MODE_TXT |
247 |
1 |
ja |
nein |
RECONNECT MANUAL |
|
load output reconnect mode as text |
| LAST_CUTOFF_AH |
254 |
1 |
ja |
nein |
0 |
Ah |
Ah counter on last cutoff |
| CURRENT_GSM_MODE |
255 |
1 |
ja |
ja |
0 |
|
current GSM mode as number |
| CURRENT_GSM_MODE_TXT |
255 |
1 |
ja |
nein |
power up |
|
current GSM mode as text |
| TCP_CONNECTION_ONLINE |
255 |
1 |
ja |
ja |
0 |
|
GSM: TCP connection online as number |
| TCP_CONNECTION_ONLINE_TXT |
255 |
1 |
ja |
nein |
no |
|
GSM: TCP connection online as text |
| INTERNET_ONLINE |
256 |
1 |
ja |
nein |
0 |
|
GSM: internet online as number |
| INTERNET_ONLINE_TXT |
256 |
1 |
ja |
nein |
no |
|
GSM: internet online as text |
| GSM_TX_BYTES |
256 |
1 |
ja |
ja |
0 |
|
GSM: number of bytes to sent |
| GSM_IP |
257 |
2 |
ja |
nein |
0.0.0.0 |
|
GSM: IP address |
| GPS_TIME_YEAR |
259 |
1 |
ja |
nein |
0 |
|
GPS time - year |
| GPS_TIME_MONTH |
259 |
1 |
ja |
nein |
0 |
|
GPS time - month |
| GPS_DATE_TIME_TXT |
259 |
3 |
ja |
nein |
1999-11-30 00:00:00 |
|
GPS time as string |
| GPS_TIME_DAY |
260 |
1 |
ja |
nein |
0 |
|
GPS time - day |
| GPS_TIME_HOUR |
260 |
1 |
ja |
nein |
0 |
|
GPS time - hour |
| GPS_TIME_MINUTE |
261 |
1 |
ja |
nein |
0 |
|
GPS time - minute |
| GPS_TIME_SECOND |
261 |
1 |
ja |
nein |
0 |
|
GPS time - second |
| MODBUS_GSM_DATA |
262 |
128 |
ja |
nein |
|
|
GSM: data to be send after connect as string |
| MODBUS_GSM_DATA_HEX |
262 |
128 |
ja |
nein |
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |
|
GSM: data to be send after connect |
| CELL1_BMS_TYPE_ID |
390 |
1 |
ja |
nein |
101 |
|
BMS: cell1 type id |
| CELL1_BMS_TYPE_TXT |
390 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell1 type as string |
| CELL1_BMS_SERNO |
391 |
1 |
ja |
nein |
42217 |
|
BMS: cell1 serial number |
| CELL1_VOLTAGE |
392 |
1 |
ja |
nein |
3304 |
mV |
Spannung Zelle 1 |
| CELL1_TEMP |
393 |
1 |
ja |
nein |
6 |
°C |
BMS Temperatur Zelle 1 |
| CELL1_PWM |
394 |
1 |
ja |
ja |
0 |
|
BMS: cell1 PWM as number |
| CELL1_PWM_PERCENT |
394 |
1 |
ja |
nein |
0 |
% |
BMS: cell1 PWM |
| CELL1_PWM_CURRENT |
394 |
1 |
ja |
nein |
0 |
A |
BMS: cell1 PWM current |
| CELL1_MODE |
394 |
1 |
ja |
ja |
0 |
|
BMS: cell1 equalization charge mode as number |
| CELL1_MODE_TXT |
394 |
1 |
ja |
nein |
auto |
|
BMS: cell1 equalization charge mode as text |
| CELL1_LVP_PROTECTION |
395 |
1 |
ja |
nein |
0 |
|
BMS: cell1 LVP mode as number |
| CELL1_LVP_PROTECTION_TXT |
395 |
1 |
ja |
nein |
off (0) |
|
BMS: cell1 LVP mode as text |
| CELL1_OVP_PROTECTION |
395 |
1 |
ja |
nein |
0 |
|
BMS: cell1 OVP mode as number |
| CELL1_OVP_PROTECTION_TXT |
395 |
1 |
ja |
nein |
off (0) |
|
BMS: cell1 OVP mode as text |
| CELL1_TEMP_PROTECTION |
396 |
1 |
ja |
nein |
0 |
|
BMS: cell1 temperature protection as number |
| CELL1_TEMP_PROTECTION_TXT |
396 |
1 |
ja |
nein |
off |
|
BMS: cell1 temperature protection as text |
| CELL2_BMS_TYPE_ID |
397 |
1 |
ja |
nein |
101 |
|
BMS: cell2 type id |
| CELL2_BMS_TYPE_TXT |
397 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell2 type as string |
| CELL2_BMS_SERNO |
398 |
1 |
ja |
nein |
42200 |
|
BMS: cell2 serial number |
| CELL2_VOLTAGE |
399 |
1 |
ja |
nein |
3306 |
mV |
Spannung Zelle 2 |
| CELL2_TEMP |
400 |
1 |
ja |
nein |
8 |
°C |
BMS Temperatur Zelle 2 |
| CELL2_PWM |
401 |
1 |
ja |
ja |
0 |
|
BMS: cell2 PWM as number |
| CELL2_PWM_PERCENT |
401 |
1 |
ja |
nein |
0 |
% |
BMS: cell2 PWM |
| CELL2_PWM_CURRENT |
401 |
1 |
ja |
nein |
0 |
A |
BMS: cell2 PWM current |
| CELL2_MODE |
401 |
1 |
ja |
ja |
0 |
|
BMS: cell2 equalization charge mode as number |
| CELL2_MODE_TXT |
401 |
1 |
ja |
nein |
auto |
|
BMS: cell2 equalization charge mode as text |
| CELL2_LVP_PROTECTION |
402 |
1 |
ja |
nein |
0 |
|
BMS: cell2 LVP mode as number |
| CELL2_LVP_PROTECTION_TXT |
402 |
1 |
ja |
nein |
off (0) |
|
BMS: cell2 LVP mode as text |
| CELL2_OVP_PROTECTION |
402 |
1 |
ja |
nein |
0 |
|
BMS: cell2 OVP mode as number |
| CELL2_OVP_PROTECTION_TXT |
402 |
1 |
ja |
nein |
off (0) |
|
BMS: cell2 OVP mode as text |
| CELL2_TEMP_PROTECTION |
403 |
1 |
ja |
nein |
0 |
|
BMS: cell2 temperature protection as number |
| CELL2_TEMP_PROTECTION_TXT |
403 |
1 |
ja |
nein |
off |
|
BMS: cell2 temperature protection as text |
| CELL3_BMS_TYPE_ID |
404 |
1 |
ja |
nein |
101 |
|
BMS: cell3 type id |
| CELL3_BMS_TYPE_TXT |
404 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell3 type as string |
| CELL3_BMS_SERNO |
405 |
1 |
ja |
nein |
42196 |
|
BMS: cell3 serial number |
| CELL3_VOLTAGE |
406 |
1 |
ja |
nein |
3300 |
mV |
Spannung Zelle 3 |
| CELL3_TEMP |
407 |
1 |
ja |
nein |
7 |
°C |
BMS Temperatur Zelle 3 |
| CELL3_PWM |
408 |
1 |
ja |
ja |
0 |
|
BMS: cell3 PWM as number |
| CELL3_PWM_PERCENT |
408 |
1 |
ja |
nein |
0 |
% |
BMS: cell3 PWM |
| CELL3_PWM_CURRENT |
408 |
1 |
ja |
nein |
0 |
A |
BMS: cell3 PWM current |
| CELL3_MODE |
408 |
1 |
ja |
ja |
0 |
|
BMS: cell3 equalization charge mode as number |
| CELL3_MODE_TXT |
408 |
1 |
ja |
nein |
auto |
|
BMS: cell3 equalization charge mode as text |
| CELL3_LVP_PROTECTION |
409 |
1 |
ja |
nein |
0 |
|
BMS: cell3 LVP mode as number |
| CELL3_LVP_PROTECTION_TXT |
409 |
1 |
ja |
nein |
off (0) |
|
BMS: cell3 LVP mode as text |
| CELL3_OVP_PROTECTION |
409 |
1 |
ja |
nein |
0 |
|
BMS: cell3 OVP mode as number |
| CELL3_OVP_PROTECTION_TXT |
409 |
1 |
ja |
nein |
off (0) |
|
BMS: cell3 OVP mode as text |
| CELL3_TEMP_PROTECTION |
410 |
1 |
ja |
nein |
0 |
|
BMS: cell3 temperature protection as number |
| CELL3_TEMP_PROTECTION_TXT |
410 |
1 |
ja |
nein |
off |
|
BMS: cell3 temperature protection as text |
| CELL4_BMS_TYPE_ID |
411 |
1 |
ja |
nein |
101 |
|
BMS: cell4 type id |
| CELL4_BMS_TYPE_TXT |
411 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell4 type as string |
| CELL4_BMS_SERNO |
412 |
1 |
ja |
nein |
42201 |
|
BMS: cell4 serial number |
| CELL4_VOLTAGE |
413 |
1 |
ja |
nein |
3308 |
mV |
Spannung Zelle 4 |
| CELL4_TEMP |
414 |
1 |
ja |
nein |
7 |
°C |
BMS Temperatur Zelle 4 |
| CELL4_PWM |
415 |
1 |
ja |
ja |
0 |
|
BMS: cell4 PWM as number |
| CELL4_PWM_PERCENT |
415 |
1 |
ja |
nein |
0 |
% |
BMS: cell4 PWM |
| CELL4_PWM_CURRENT |
415 |
1 |
ja |
nein |
0 |
A |
BMS: cell4 PWM current |
| CELL4_MODE |
415 |
1 |
ja |
ja |
0 |
|
BMS: cell4 equalization charge mode as number |
| CELL4_MODE_TXT |
415 |
1 |
ja |
nein |
auto |
|
BMS: cell4 equalization charge mode as text |
| CELL4_LVP_PROTECTION |
416 |
1 |
ja |
nein |
0 |
|
BMS: cell4 LVP mode as number |
| CELL4_LVP_PROTECTION_TXT |
416 |
1 |
ja |
nein |
off (0) |
|
BMS: cell4 LVP mode as text |
| CELL4_OVP_PROTECTION |
416 |
1 |
ja |
nein |
0 |
|
BMS: cell4 OVP mode as number |
| CELL4_OVP_PROTECTION_TXT |
416 |
1 |
ja |
nein |
off (0) |
|
BMS: cell4 OVP mode as text |
| CELL4_TEMP_PROTECTION |
417 |
1 |
ja |
nein |
0 |
|
BMS: cell4 temperature protection as number |
| CELL4_TEMP_PROTECTION_TXT |
417 |
1 |
ja |
nein |
off |
|
BMS: cell4 temperature protection as text |
| CELL5_BMS_TYPE_ID |
418 |
1 |
ja |
nein |
101 |
|
BMS: cell5 type id |
| CELL5_BMS_TYPE_TXT |
418 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell5 type as string |
| CELL5_BMS_SERNO |
419 |
1 |
ja |
nein |
42206 |
|
BMS: cell5 serial number |
| CELL5_VOLTAGE |
420 |
1 |
ja |
nein |
3304 |
mV |
Spannung Zelle 5 |
| CELL5_TEMP |
421 |
1 |
ja |
nein |
7 |
°C |
BMS Temperatur Zelle 5 |
| CELL5_PWM |
422 |
1 |
ja |
ja |
0 |
|
BMS: cell5 PWM as number |
| CELL5_PWM_PERCENT |
422 |
1 |
ja |
nein |
0 |
% |
BMS: cell5 PWM |
| CELL5_PWM_CURRENT |
422 |
1 |
ja |
nein |
0 |
A |
BMS: cell5 PWM current |
| CELL5_MODE |
422 |
1 |
ja |
ja |
0 |
|
BMS: cell5 equalization charge mode as number |
| CELL5_MODE_TXT |
422 |
1 |
ja |
nein |
auto |
|
BMS: cell5 equalization charge mode as text |
| CELL5_LVP_PROTECTION |
423 |
1 |
ja |
nein |
0 |
|
BMS: cell5 LVP mode as number |
| CELL5_LVP_PROTECTION_TXT |
423 |
1 |
ja |
nein |
off (0) |
|
BMS: cell5 LVP mode as text |
| CELL5_OVP_PROTECTION |
423 |
1 |
ja |
nein |
0 |
|
BMS: cell5 OVP mode as number |
| CELL5_OVP_PROTECTION_TXT |
423 |
1 |
ja |
nein |
off (0) |
|
BMS: cell5 OVP mode as text |
| CELL5_TEMP_PROTECTION |
424 |
1 |
ja |
nein |
0 |
|
BMS: cell5 temperature protection as number |
| CELL5_TEMP_PROTECTION_TXT |
424 |
1 |
ja |
nein |
off |
|
BMS: cell5 temperature protection as text |
| CELL6_BMS_TYPE_ID |
425 |
1 |
ja |
nein |
101 |
|
BMS: cell6 type id |
| CELL6_BMS_TYPE_TXT |
425 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell6 type as string |
| CELL6_BMS_SERNO |
426 |
1 |
ja |
nein |
42198 |
|
BMS: cell6 serial number |
| CELL6_VOLTAGE |
427 |
1 |
ja |
nein |
3304 |
mV |
Spannung Zelle 6 |
| CELL6_TEMP |
428 |
1 |
ja |
nein |
8 |
°C |
BMS Temperatur Zelle 6 |
| CELL6_PWM |
429 |
1 |
ja |
ja |
0 |
|
BMS: cell6 PWM as number |
| CELL6_PWM_PERCENT |
429 |
1 |
ja |
nein |
0 |
% |
BMS: cell6 PWM |
| CELL6_PWM_CURRENT |
429 |
1 |
ja |
nein |
0 |
A |
BMS: cell6 PWM |
| CELL6_MODE |
429 |
1 |
ja |
ja |
0 |
|
BMS: cell6 equalization charge mode as number |
| CELL6_MODE_TXT |
429 |
1 |
ja |
nein |
auto |
|
BMS: cell6 equalization charge mode as text |
| CELL6_LVP_PROTECTION |
430 |
1 |
ja |
nein |
0 |
|
BMS: cell6 LVP mode as number |
| CELL6_LVP_PROTECTION_TXT |
430 |
1 |
ja |
nein |
off (0) |
|
BMS: cell6 LVP mode as text |
| CELL6_OVP_PROTECTION |
430 |
1 |
ja |
nein |
0 |
|
BMS: cell6 OVP mode as number |
| CELL6_OVP_PROTECTION_TXT |
430 |
1 |
ja |
nein |
off (0) |
|
BMS: cell6 OVP mode as text |
| CELL6_TEMP_PROTECTION |
431 |
1 |
ja |
nein |
0 |
|
BMS: cell6 temperature protection as number |
| CELL6_TEMP_PROTECTION_TXT |
431 |
1 |
ja |
nein |
off |
|
BMS: cell6 temperature protection as text |
| CELL7_BMS_TYPE_ID |
432 |
1 |
ja |
nein |
101 |
|
BMS: cell7 type id |
| CELL7_BMS_TYPE_TXT |
432 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell7 type as string |
| CELL7_BMS_SERNO |
433 |
1 |
ja |
nein |
42195 |
|
BMS: cell7 serial number |
| CELL7_VOLTAGE |
434 |
1 |
ja |
nein |
3306 |
mV |
Spannung Zelle 7 |
| CELL7_TEMP |
435 |
1 |
ja |
nein |
7 |
°C |
BMS Temperatur Zelle 7 |
| CELL7_PWM |
436 |
1 |
ja |
ja |
0 |
|
BMS: cell7 PWM as number |
| CELL7_PWM_PERCENT |
436 |
1 |
ja |
nein |
0 |
% |
BMS: cell7 PWM |
| CELL7_PWM_CURRENT |
436 |
1 |
ja |
nein |
0 |
A |
BMS: cell7 PWM current |
| CELL7_MODE |
436 |
1 |
ja |
ja |
0 |
|
BMS: cell7 equalization charge mode as number |
| CELL7_MODE_TXT |
436 |
1 |
ja |
nein |
auto |
|
BMS: cell7 equalization charge mode as text |
| CELL7_LVP_PROTECTION |
437 |
1 |
ja |
nein |
0 |
|
BMS: cell7 LVP mode as number |
| CELL7_LVP_PROTECTION_TXT |
437 |
1 |
ja |
nein |
off (0) |
|
BMS: cell7 LVP mode as text |
| CELL7_OVP_PROTECTION |
437 |
1 |
ja |
nein |
0 |
|
BMS: cell7 OVP mode as number |
| CELL7_OVP_PROTECTION_TXT |
437 |
1 |
ja |
nein |
off (0) |
|
BMS: cell7 OVP mode as text |
| CELL7_TEMP_PROTECTION |
438 |
1 |
ja |
nein |
0 |
|
BMS: cell7 temperature protection as number |
| CELL7_TEMP_PROTECTION_TXT |
438 |
1 |
ja |
nein |
off |
|
BMS: cell7 temperature protection as text |
| CELL8_BMS_TYPE_ID |
439 |
1 |
ja |
nein |
101 |
|
BMS: cell8 type id |
| CELL8_BMS_TYPE_TXT |
439 |
1 |
ja |
nein |
LiPro 1-6 active |
|
BMS: cell8 type as string |
| CELL8_BMS_SERNO |
440 |
1 |
ja |
nein |
1 |
|
BMS: cell8 serial number |
| CELL8_VOLTAGE |
441 |
1 |
ja |
nein |
3304 |
mV |
Spannung Zelle 8 |
| CELL8_TEMP |
442 |
1 |
ja |
nein |
7 |
°C |
BMS Temperatur Zelle 8 |
| CELL8_PWM |
443 |
1 |
ja |
ja |
0 |
|
BMS: cell8 PWM as number |
| CELL8_PWM_PERCENT |
443 |
1 |
ja |
nein |
0 |
% |
BMS: cell8 PWM |
| CELL8_PWM_CURRENT |
443 |
1 |
ja |
nein |
0 |
A |
BMS: cell8 PWM current |
| CELL8_MODE |
443 |
1 |
ja |
ja |
0 |
|
BMS: cell8 equalization charge mode as number |
| CELL8_MODE_TXT |
443 |
1 |
ja |
nein |
auto |
|
BMS: cell8 equalization charge mode as text |
| CELL8_LVP_PROTECTION |
444 |
1 |
ja |
nein |
0 |
|
BMS: cell8 LVP mode as number |
| CELL8_LVP_PROTECTION_TXT |
444 |
1 |
ja |
nein |
off (0) |
|
BMS: cell8 LVP mode as text |
| CELL8_OVP_PROTECTION |
444 |
1 |
ja |
nein |
0 |
|
BMS: cell8 OVP mode as number |
| CELL8_OVP_PROTECTION_TXT |
444 |
1 |
ja |
nein |
off (0) |
|
BMS: cell8 OVP mode as text |
| CELL8_TEMP_PROTECTION |
445 |
1 |
ja |
nein |
0 |
|
BMS: cell8 temperature protection as number |
| CELL8_TEMP_PROTECTION_TXT |
445 |
1 |
ja |
nein |
off |
|
BMS: cell8 temperature protection as text |
| CELL9_BMS_TYPE_ID |
446 |
1 |
ja |
nein |
0 |
|
BMS: cell9 type id |
| CELL9_BMS_TYPE_TXT |
446 |
1 |
ja |
nein |
no BMS |
|
BMS: cell9 type as string |
| CELL9_BMS_SERNO |
447 |
1 |
ja |
nein |
0 |
|
BMS: cell9 serial number |
| CELL9_VOLTAGE |
448 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 9 |
| CELL9_TEMP |
449 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 9 |
| CELL9_PWM |
450 |
1 |
ja |
ja |
0 |
|
BMS: cell9 PWM as number |
| CELL9_PWM_PERCENT |
450 |
1 |
ja |
nein |
0 |
% |
BMS: cell9 PWM |
| CELL9_PWM_CURRENT |
450 |
1 |
ja |
nein |
0 |
A |
BMS: cell9 PWM current |
| CELL9_MODE |
450 |
1 |
ja |
ja |
0 |
|
BMS: cell9 equalization charge mode as number |
| CELL9_MODE_TXT |
450 |
1 |
ja |
nein |
auto |
|
BMS: cell9 equalization charge mode as text |
| CELL9_LVP_PROTECTION |
451 |
1 |
ja |
nein |
0 |
|
BMS: cell9 LVP mode as number |
| CELL9_LVP_PROTECTION_TXT |
451 |
1 |
ja |
nein |
off (0) |
|
BMS: cell9 LVP mode as text |
| CELL9_OVP_PROTECTION |
451 |
1 |
ja |
nein |
0 |
|
BMS: cell9 OVP mode as number |
| CELL9_OVP_PROTECTION_TXT |
451 |
1 |
ja |
nein |
off (0) |
|
BMS: cell9 OVP mode as text |
| CELL9_TEMP_PROTECTION |
452 |
1 |
ja |
nein |
0 |
|
BMS: cell9 temperature protection as number |
| CELL9_TEMP_PROTECTION_TXT |
452 |
1 |
ja |
nein |
off |
|
BMS: cell9 temperature protection as text |
| CELL10_BMS_TYPE_ID |
453 |
1 |
ja |
nein |
0 |
|
BMS: cell10 type id |
| CELL10_BMS_TYPE_TXT |
453 |
1 |
ja |
nein |
no BMS |
|
BMS: cell10 type as string |
| CELL10_BMS_SERNO |
454 |
1 |
ja |
nein |
0 |
|
BMS: cell10 serial number |
| CELL10_VOLTAGE |
455 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 10 |
| CELL10_TEMP |
456 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 10 |
| CELL10_PWM |
457 |
1 |
ja |
ja |
0 |
|
BMS: cell10 PWM as number |
| CELL10_PWM_PERCENT |
457 |
1 |
ja |
nein |
0 |
% |
BMS: cell10 PWM |
| CELL10_PWM_CURRENT |
457 |
1 |
ja |
nein |
0 |
A |
BMS: cell10 PWM current |
| CELL10_MODE |
457 |
1 |
ja |
ja |
0 |
|
BMS: cell10 equalization charge mode as number |
| CELL10_MODE_TXT |
457 |
1 |
ja |
nein |
auto |
|
BMS: cell10 equalization charge mode as text |
| CELL10_LVP_PROTECTION |
458 |
1 |
ja |
nein |
0 |
|
BMS: cell10 LVP mode as number |
| CELL10_LVP_PROTECTION_TXT |
458 |
1 |
ja |
nein |
off (0) |
|
BMS: cell10 LVP mode as text |
| CELL10_OVP_PROTECTION |
458 |
1 |
ja |
nein |
0 |
|
BMS: cell10 OVP mode as number |
| CELL10_OVP_PROTECTION_TXT |
458 |
1 |
ja |
nein |
off (0) |
|
BMS: cell10 OVP mode as text |
| CELL10_TEMP_PROTECTION |
459 |
1 |
ja |
nein |
0 |
|
BMS: cell10 temperature protection as number |
| CELL10_TEMP_PROTECTION_TXT |
459 |
1 |
ja |
nein |
off |
|
BMS: cell10 temperature protection as text |
| CELL11_BMS_TYPE_ID |
460 |
1 |
ja |
nein |
0 |
|
BMS: cell11 type id |
| CELL11_BMS_TYPE_TXT |
460 |
1 |
ja |
nein |
no BMS |
|
BMS: cell11 type as string |
| CELL11_BMS_SERNO |
461 |
1 |
ja |
nein |
0 |
|
BMS: cell11 serial number |
| CELL11_VOLTAGE |
462 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 11 |
| CELL11_TEMP |
463 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 11 |
| CELL11_PWM |
464 |
1 |
ja |
ja |
0 |
|
BMS: cell11 PWM as number |
| CELL11_PWM_PERCENT |
464 |
1 |
ja |
nein |
0 |
% |
BMS: cell11 PWM |
| CELL11_PWM_CURRENT |
464 |
1 |
ja |
nein |
0 |
A |
BMS: cell11 PWM current |
| CELL11_MODE |
464 |
1 |
ja |
ja |
0 |
|
BMS: cell11 equalization charge mode as number |
| CELL11_MODE_TXT |
464 |
1 |
ja |
nein |
auto |
|
BMS: cell11 equalization charge mode as text |
| CELL11_LVP_PROTECTION |
465 |
1 |
ja |
nein |
0 |
|
BMS: cell11 LVP mode as number |
| CELL11_LVP_PROTECTION_TXT |
465 |
1 |
ja |
nein |
off (0) |
|
BMS: cell11 LVP mode as text |
| CELL11_OVP_PROTECTION |
465 |
1 |
ja |
nein |
0 |
|
BMS: cell11 OVP mode as number |
| CELL11_OVP_PROTECTION_TXT |
465 |
1 |
ja |
nein |
off (0) |
|
BMS: cell11 OVP mode as text |
| CELL11_TEMP_PROTECTION |
466 |
1 |
ja |
nein |
0 |
|
BMS: cell11 temperature protection as number |
| CELL11_TEMP_PROTECTION_TXT |
466 |
1 |
ja |
nein |
off |
|
BMS: cell11 temperature protection as text |
| CELL12_BMS_TYPE_ID |
467 |
1 |
ja |
nein |
0 |
|
BMS: cell12 type id |
| CELL12_BMS_TYPE_TXT |
467 |
1 |
ja |
nein |
no BMS |
|
BMS: cell12 type as string |
| CELL12_BMS_SERNO |
478 |
1 |
ja |
nein |
0 |
|
BMS: cell12 serial number |
| CELL12_VOLTAGE |
469 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 12 |
| CELL12_TEMP |
470 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 12 |
| CELL12_PWM |
471 |
1 |
ja |
ja |
0 |
|
BMS: cell12 PWM as number |
| CELL12_PWM_PERCENT |
471 |
1 |
ja |
nein |
0 |
% |
BMS: cell12 PWM |
| CELL12_PWM_CURRENT |
471 |
1 |
ja |
nein |
0 |
A |
BMS: cell12 PWM current |
| CELL12_MODE |
471 |
1 |
ja |
ja |
0 |
|
BMS: cell12 equalization charge mode as number |
| CELL12_MODE_TXT |
471 |
1 |
ja |
nein |
auto |
|
BMS: cell12 equalization charge mode as text |
| CELL12_LVP_PROTECTION |
472 |
1 |
ja |
nein |
0 |
|
BMS: cell12 LVP mode as number |
| CELL12_LVP_PROTECTION_TXT |
472 |
1 |
ja |
nein |
off (0) |
|
BMS: cell12 LVP mode as text |
| CELL12_OVP_PROTECTION |
472 |
1 |
ja |
nein |
0 |
|
BMS: cell12 OVP mode as number |
| CELL12_OVP_PROTECTION_TXT |
472 |
1 |
ja |
nein |
off (0) |
|
BMS: cell12 OVP mode as text |
| CELL12_TEMP_PROTECTION |
473 |
1 |
ja |
nein |
0 |
|
BMS: cell12 temperature protection as number |
| CELL12_TEMP_PROTECTION_TXT |
473 |
1 |
ja |
nein |
off |
|
BMS: cell12 temperature protection as text |
| CELL13_BMS_TYPE_ID |
474 |
1 |
ja |
nein |
0 |
|
BMS: cell13 type id |
| CELL13_BMS_TYPE_TXT |
474 |
1 |
ja |
nein |
no BMS |
|
BMS: cell13 type as string |
| CELL13_BMS_SERNO |
475 |
1 |
ja |
nein |
0 |
|
BMS: cell13 serial number |
| CELL13_VOLTAGE |
476 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 13 |
| CELL13_TEMP |
477 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 13 |
| CELL13_PWM |
478 |
1 |
ja |
ja |
0 |
|
BMS: cell13 PWM as number |
| CELL13_PWM_PERCENT |
478 |
1 |
ja |
nein |
0 |
% |
BMS: cell13 PWM |
| CELL13_PWM_CURRENT |
478 |
1 |
ja |
nein |
0 |
A |
BMS: cell13 PWM current |
| CELL13_MODE |
478 |
1 |
ja |
ja |
0 |
|
BMS: cell13 equalization charge mode as number |
| CELL13_MODE_TXT |
478 |
1 |
ja |
nein |
auto |
|
BMS: cell13 equalization charge mode as text |
| CELL13_LVP_PROTECTION |
479 |
1 |
ja |
nein |
0 |
|
BMS: cell13 LVP mode as number |
| CELL13_LVP_PROTECTION_TXT |
479 |
1 |
ja |
nein |
off (0) |
|
BMS: cell13 LVP mode as text |
| CELL13_OVP_PROTECTION |
479 |
1 |
ja |
nein |
0 |
|
BMS: cell13 OVP mode as number |
| CELL13_OVP_PROTECTION_TXT |
479 |
1 |
ja |
nein |
off (0) |
|
BMS: cell13 OVP mode as text |
| CELL13_TEMP_PROTECTION |
480 |
1 |
ja |
nein |
0 |
|
BMS: cell13 temperature protection as number |
| CELL13_TEMP_PROTECTION_TXT |
480 |
1 |
ja |
nein |
off |
|
BMS: cell13 temperature protection as text |
| CELL14_BMS_TYPE_ID |
481 |
1 |
ja |
nein |
0 |
|
BMS: cell14 type id |
| CELL14_BMS_TYPE_TXT |
481 |
1 |
ja |
nein |
no BMS |
|
BMS: cell14 type as string |
| CELL14_BMS_SERNO |
482 |
1 |
ja |
nein |
0 |
|
BMS: cell14 serial number |
| CELL14_VOLTAGE |
483 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 14 |
| CELL14_TEMP |
484 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 14 |
| CELL14_PWM |
485 |
1 |
ja |
ja |
0 |
|
BMS: cell14 PWM as number |
| CELL14_PWM_PERCENT |
485 |
1 |
ja |
nein |
0 |
% |
BMS: cell14 PWM |
| CELL14_PWM_CURRENT |
485 |
1 |
ja |
nein |
0 |
A |
BMS: cell14 PWM current |
| CELL14_MODE |
485 |
1 |
ja |
ja |
0 |
|
BMS: cell14 equalization charge mode as number |
| CELL14_MODE_TXT |
485 |
1 |
ja |
nein |
auto |
|
BMS: cell14 equalization charge mode as text |
| CELL14_LVP_PROTECTION |
486 |
1 |
ja |
nein |
0 |
|
BMS: cell14 LVP mode as number |
| CELL14_LVP_PROTECTION_TXT |
486 |
1 |
ja |
nein |
off (0) |
|
BMS: cell14 LVP mode as text |
| CELL14_OVP_PROTECTION |
486 |
1 |
ja |
nein |
0 |
|
BMS: cell14 OVP mode as number |
| CELL14_OVP_PROTECTION_TXT |
486 |
1 |
ja |
nein |
off (0) |
|
BMS: cell14 OVP mode as text |
| CELL14_TEMP_PROTECTION |
487 |
1 |
ja |
nein |
0 |
|
BMS: cell14 temperature protection as number |
| CELL14_TEMP_PROTECTION_TXT |
487 |
1 |
ja |
nein |
off |
|
BMS: cell14 temperature protection as text |
| CELL15_BMS_TYPE_ID |
488 |
1 |
ja |
nein |
0 |
|
BMS: cell15 type id |
| CELL15_BMS_TYPE_TXT |
488 |
1 |
ja |
nein |
no BMS |
|
BMS: cell15 type as string |
| CELL15_BMS_SERNO |
489 |
1 |
ja |
nein |
0 |
|
BMS: cell15 serial number |
| CELL15_VOLTAGE |
490 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 15 |
| CELL15_TEMP |
491 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 15 |
| CELL15_PWM |
492 |
1 |
ja |
ja |
0 |
|
BMS: cell15 PWM as number |
| CELL15_PWM_PERCENT |
492 |
1 |
ja |
nein |
0 |
% |
BMS: cell15 PWM |
| CELL15_PWM_CURRENT |
492 |
1 |
ja |
nein |
0 |
A |
BMS: cell15 PWM current |
| CELL15_MODE |
492 |
1 |
ja |
ja |
0 |
|
BMS: cell15 equalization charge mode as number |
| CELL15_MODE_TXT |
492 |
1 |
ja |
nein |
auto |
|
BMS: cell15 equalization charge mode as text |
| CELL15_LVP_PROTECTION |
493 |
1 |
ja |
nein |
0 |
|
BMS: cell15 LVP mode as number |
| CELL15_LVP_PROTECTION_TXT |
493 |
1 |
ja |
nein |
off (0) |
|
BMS: cell15 LVP mode as text |
| CELL15_OVP_PROTECTION |
493 |
1 |
ja |
nein |
0 |
|
BMS: cell15 OVP mode as number |
| CELL15_OVP_PROTECTION_TXT |
493 |
1 |
ja |
nein |
off (0) |
|
BMS: cell15 OVP mode as text |
| CELL15_TEMP_PROTECTION |
494 |
1 |
ja |
nein |
0 |
|
BMS: cell15 temperature protection as number |
| CELL15_TEMP_PROTECTION_TXT |
494 |
1 |
ja |
nein |
off |
|
BMS: cell15 temperature protection as text |
| CELL16_BMS_TYPE_ID |
495 |
1 |
ja |
nein |
0 |
|
BMS: cell16 type id |
| CELL16_BMS_TYPE_TXT |
495 |
1 |
ja |
nein |
no BMS |
|
BMS: cell16 type as string |
| CELL16_BMS_SERNO |
496 |
1 |
ja |
nein |
0 |
|
BMS: cell16 serial number |
| CELL16_VOLTAGE |
497 |
1 |
ja |
nein |
0 |
mV |
Spannung Zelle 16 |
| CELL16_TEMP |
498 |
1 |
ja |
nein |
0 |
°C |
BMS Temperatur Zelle 16 |
| CELL16_PWM |
499 |
1 |
ja |
ja |
0 |
|
BMS: cell16 PWM as number |
| CELL16_PWM_PERCENT |
499 |
1 |
ja |
nein |
0 |
% |
BMS: cell16 PWM |
| CELL16_PWM_CURRENT |
499 |
1 |
ja |
nein |
0 |
A |
BMS: cell16 PWM current |
| CELL16_MODE |
499 |
1 |
ja |
ja |
0 |
|
BMS: cell16 equalization charge mode as number |
| CELL16_MODE_TXT |
499 |
1 |
ja |
nein |
auto |
|
BMS: cell16 equalization charge mode as text |
| CELL16_LVP_PROTECTION |
500 |
1 |
ja |
nein |
0 |
|
BMS: cell16 LVP mode as number |
| CELL16_LVP_PROTECTION_TXT |
500 |
1 |
ja |
nein |
off (0) |
|
BMS: cell16 LVP mode as text |
| CELL16_OVP_PROTECTION |
500 |
1 |
ja |
nein |
0 |
|
BMS: cell16 OVP mode as number |
| CELL16_OVP_PROTECTION_TXT |
500 |
1 |
ja |
nein |
off (0) |
|
BMS: cell16 OVP mode as text |
| CELL16_TEMP_PROTECTION |
501 |
1 |
ja |
nein |
0 |
|
BMS: cell16 temperature protection as number |
| CELL16_TEMP_PROTECTION_TXT |
501 |
1 |
ja |
nein |
off |
|
BMS: cell16 temperature protection as text |
| BATT_CURRENT_LIMIT |
502 |
1 |
ja |
nein |
300 |
A |
battery current limit |
| BATT_ABSORPTION_VOLTAGE |
503 |
2 |
ja |
nein |
28 |
V |
battery absorption voltage |
| BATT_ABSORPTION_EXIT_VOLTAGE |
505 |
2 |
ja |
nein |
27.52 |
V |
battery absorption exit voltage |
| BATT_FLOAT_VOLTAGE |
507 |
2 |
ja |
nein |
27.6 |
V |
battery float voltage |
| BATT_FLOAT_EXIT_VOLTAGE |
509 |
2 |
ja |
nein |
27.04 |
V |
battery float exit voltage |
| BATT_EQUALIZE_VOLTAGE |
511 |
2 |
ja |
nein |
29.6 |
V |
battery equalize voltage |
| BATT_CUT_OFF_VOLTAGE |
513 |
2 |
ja |
nein |
24 |
V |
battery LVP cut off voltage |
| BATT_CUT_OFF_RECOVERY_VOLTAGE |
515 |
2 |
ja |
nein |
25.6 |
V |
battery LVP cut off recovery voltage |
| SL_CURRENT_LED_PWM |
517 |
1 |
ja |
nein |
200 |
|
streetlight: current PWM as number |
| SL_CURRENT_LED_PWM_PERCENT |
517 |
1 |
ja |
nein |
78.4 |
% |
streetlight: current PWM |
| SL_LOW_BATT_MODE |
518 |
1 |
ja |
nein |
0 |
|
streetlight: current brightness reduction due low battery voltage as number |
| SL_LOW_BATT_MODE_TXT |
518 |
1 |
ja |
nein |
off |
|
streetlight: current brightness reduction due low battery voltage as text |
| ERROR_MASTER |
519 |
1 |
ja |
nein |
0 |
|
ERROR master as number |
| ERROR_MASTER_TXT |
519 |
1 |
ja |
nein |
no error (0) |
|
ERROR master |
| ERROR_HV_INPUT |
519 |
1 |
ja |
nein |
0 |
|
ERROR high voltage input as number |
| ERROR_HV_INPUT_TXT |
519 |
1 |
ja |
nein |
input voltage is OK (0) |
|
ERROR high voltage input |
| ERROR_HV_BATT |
520 |
1 |
ja |
nein |
0 |
|
ERROR high voltage battery as number |
| ERROR_HV_BATT_TXT |
520 |
1 |
ja |
nein |
battery voltage is OK (0) |
|
ERROR high voltage battery |
| ERROR_TEMP_INT |
520 |
1 |
ja |
nein |
0 |
|
ERROR high internal temperature as number |
| ERROR_TEMP_INT_TXT |
520 |
1 |
ja |
nein |
internal temperature is OK (0) |
|
ERROR high internal temperature |
| ERROR_LVP_BATT |
521 |
1 |
ja |
nein |
0 |
|
ERROR battery LVP active as number |
| ERROR_LVP_BATT_TXT |
521 |
1 |
ja |
nein |
No error (0) |
|
ERROR battery LVP |
| ERROR_LVP_CELL |
521 |
1 |
ja |
nein |
0 |
|
ERROR cell LVP active as number |
| ERROR_LVP_CELL_TXT |
521 |
1 |
ja |
nein |
No error (0) |
|
ERROR cell LVP |
| ERROR_UVP_BATT |
522 |
1 |
ja |
nein |
0 |
|
ERROR battery UVP active as number |
| ERROR_UVP_BATT_TXT |
522 |
1 |
ja |
nein |
No error (0) |
|
ERROR battery UVP |
| ERROR_OVP_CELL |
522 |
1 |
ja |
nein |
0 |
|
ERROR cell OVP active as number |
| ERROR_OVP_CELL_TXT |
522 |
1 |
ja |
nein |
No error (0) |
|
ERROR cell OVP |
| ERROR_TEMP_BATT |
523 |
1 |
ja |
nein |
0 |
|
ERROR battery temperature as number |
| ERROR_TEMP_BATT_TXT |
523 |
1 |
ja |
nein |
battery temperature is OK (0) |
|
ERROR battery temperature |
| ERROR_WARN_I_LIM_ACTIVE |
523 |
1 |
ja |
nein |
0 |
|
ERROR current limit protection as number |
| ERROR_WARN_I_LIM_ACTIVE_TXT |
523 |
1 |
ja |
nein |
current is OK (0) |
|
ERROR current limit protection |
| MB_COMM_ERROR |
524 |
1 |
ja |
nein |
0 |
|
Modbus communication ERROR as number |
| MB_COMM_ERROR_TXT |
524 |
1 |
ja |
nein |
no modbus error (0) |
|
ERROR Modbus communication |
| ERRCODE_TEMP_SENSOR_BATT |
524 |
1 |
ja |
nein |
0 |
|
ERRORcode temperature sensor battery as number |
| ERRCODE_TEMP_SENSOR_BATT_TXT |
524 |
1 |
ja |
nein |
battery temperature sensor is OK (0) |
|
ERROR temperature sensor battery |
| RESET_STATUS |
525 |
1 |
ja |
nein |
2 |
|
RESET status as number |
| RESET_STATUS_TXT |
525 |
1 |
ja |
nein |
external reset (2) |
|
RESET status |
| BMS_SYSTEM_WARNING |
525 |
1 |
ja |
nein |
0 |
|
BMS System Status |
| BMS_SYSTEM_WARNING_TXT |
525 |
1 |
ja |
nein |
FB-MODE off (0) |
|
BMS System Status |
| I_LIM_EXT |
526 |
1 |
ja |
nein |
255 |
A |
current limit by external control output |
| DIVERSION_PWM_OUT |
527 |
1 |
ja |
nein |
0 |
|
PWM diversion as number |
| DIVERSION_PWM_OUT_PERCENT |
527 |
1 |
ja |
nein |
0 |
% |
PWM diversion |
| OUTPUT_STATE |
528 |
1 |
ja |
nein |
1 |
|
switching state load output as number |
| OUTPUT_STATE_TXT |
528 |
1 |
ja |
nein |
user on (1) |
|
Status GC Ausgang |
| CHARGER_STATE |
529 |
1 |
ja |
nein |
2 |
|
current charger mode as number |
| CHARGER_STATE_TXT |
529 |
1 |
ja |
nein |
MPPT (2) |
|
current charger mode as text |
| CHARGER_STATE_EXTENDED_TXT |
529 |
1 |
ja |
nein |
MPPT |
|
Lademodus mit erweiterten Angaben |
| EXTERNAL_ALARM |
529 |
1 |
ja |
nein |
0 |
|
external alarm as number |
| EXTERNAL_ALARM_TXT |
529 |
1 |
ja |
nein |
no external alarm (0) |
|
external alarm as text |
| MPP_PWM |
530 |
1 |
ja |
nein |
357 |
|
MPP PWM as number |
| ACT_PWM |
531 |
1 |
ja |
nein |
357 |
|
actual MPP PWM as number |
| P_INPUT |
532 |
1 |
ja |
nein |
1 |
W |
Leistung am Solareingang |
| P_OUTPUT |
533 |
1 |
ja |
nein |
1 |
W |
Leistung Abgabe gesamt |
| ABS_EQUALIZE_HOLD_COUNTER |
534 |
1 |
ja |
nein |
5 |
Minuten |
equalize and absorption time counter |
| FLOAT_EXIT_COUNTER |
535 |
1 |
ja |
nein |
0 |
Minuten |
float exit time counter |
| INTERNAL_TEMP |
536 |
1 |
ja |
nein |
23 |
°C |
GC interne Temperatur |
| BATT_TEMP |
537 |
1 |
ja |
nein |
6.5 |
°C |
Batterie Temperatur |
| U_EXTERNAL_INPUT1 |
538 |
2 |
ja |
nein |
0 |
V |
actual voltage at external input1 |
| CURRENT_EXTERNAL_INPUT1 |
538 |
2 |
ja |
nein |
0 |
A |
Strom (external input1 current) |
| INVERTER_CURRENT_EXTERNAL_INPUT1 |
538 |
2 |
ja |
nein |
0 |
A |
Wechselrichter Strom |
| P_EXTERNAL_INPUT1 |
546 |
2 |
ja |
nein |
0 |
W |
Power on external input 1 |
| INVERTER_POWER_EXTERNAL_INPUT1 |
546 |
2 |
ja |
nein |
0 |
W |
Wechselrichter Leistung am input1 |
| U_EXTERNAL_INPUT2 |
540 |
2 |
ja |
nein |
0 |
V |
actual voltage at external input2 |
| CURRENT_EXTERNAL_INPUT2 |
540 |
2 |
ja |
nein |
0 |
A |
external input2 current |
| U_EXTERNAL_INPUT3 |
542 |
2 |
ja |
nein |
0 |
V |
actual voltage at external input3 |
| CURRENT_EXTERNAL_INPUT3 |
542 |
2 |
ja |
nein |
0 |
A |
external input3 current |
| U_EXTERNAL_INPUT4 |
544 |
2 |
ja |
nein |
0 |
V |
actual voltage at external input4 |
| CURRENT_EXTERNAL_INPUT4 |
544 |
2 |
ja |
nein |
0 |
A |
external input4 current |
| U_BATT |
546 |
2 |
ja |
nein |
26.43 |
V |
Batteriespannung |
| U_INPUT |
548 |
2 |
ja |
nein |
39.51 |
V |
Spannung Solargenerator |
| I_BATT_IN_AVG |
552 |
2 |
ja |
nein |
0 |
A |
Solar-Modulstrom |
| I_OUT_INTERNAL |
554 |
2 |
ja |
nein |
0 |
A |
Strom am GC Ausgang |
| P_OUT_INTERNAL |
554 |
2 |
ja |
nein |
0 |
W |
Abgabe Leistung GC Ausgang |
| I_BATT |
556 |
2 |
ja |
nein |
-0 |
A |
Batteriestrom mit externen Sensoren und Eigenverbrauch |
| LONGITUDE |
558 |
2 |
ja |
nein |
5.8774717541114E-39 |
|
GPS: longitude |
| LATITUDE |
560 |
2 |
ja |
nein |
5.8774717541114E-39 |
|
GPS: latitude |
| ALTITUDE |
562 |
2 |
ja |
nein |
5.8774717541114E-39 |
|
GPS: altitude |
| COUNTER_BATT_AH |
564 |
2 |
ja |
nein |
216.67 |
Ah |
Aktuelle Batteriekapazität |
| COUNTER_BATT_PERCENT |
564 |
2 |
ja |
nein |
72.2 |
% |
Aktuelle Batteriekapazität |
| COUNTER_WH_IN_DAY_GC_140_30 |
566 |
2 |
ja |
nein |
21 |
Wh |
Ladung heute IN |
| COUNTER_WH_OUT_DAY_GC_140_30 |
568 |
2 |
ja |
nein |
2 |
Wh |
Ladung heute OUT |
| COUNTER_WH_IN_LAST_DAY_GC_140_30 |
570 |
2 |
ja |
nein |
48 |
Wh |
Ladung gestern IN |
| COUNTER_WH_OUT_LAST_DAY_GC_140_30 |
572 |
2 |
ja |
nein |
5 |
Wh |
Ladung gestern OUT |
| COUNTER_WH_IN_TOTAL_GC_140_30 |
574 |
2 |
ja |
nein |
722419 |
Wh |
Ladung gesamt IN |
| COUNTER_WH_OUT_TOTAL_GC_140_30 |
576 |
2 |
ja |
nein |
629363 |
Wh |
Ladung gesamt OUT |
| LOCAL_TIME |
578 |
3 |
ja |
ja |
2026-01-03 13:33:01 |
|
Gerätezeit des GC |
| LOCAL_TIME_YEAR |
578 |
1 |
ja |
ja |
26 |
|
Gerätezeit - Jahr |
| LOCAL_TIME_MONTH |
578 |
1 |
ja |
ja |
1 |
|
Gerätezeit - Monat |
| LOCAL_TIME_DAY |
579 |
1 |
ja |
ja |
3 |
|
Gerätezeit - Tag |
| LOCAL_TIME_HOUR |
579 |
1 |
ja |
ja |
13 |
|
Gerätezeit - Stunde |
| LOCAL_TIME_MINUTE |
580 |
1 |
ja |
ja |
33 |
|
Gerätezeit - Minute |
| LOCAL_TIME_SECOND |
580 |
1 |
ja |
ja |
1 |
|
Gerätezeit- Sekunde |
| LOCAL_TIME_TIMEZONE |
581 |
1 |
ja |
ja |
1 |
|
Gerätezeit Zeitzone |
| LOCAL_TIME_DAYLIGHT_SAVING_TIME |
581 |
1 |
ja |
ja |
0 |
Stunden |
Geräzezeit Zeitverschiebung |
| LOG1_TIME |
582 |
3 |
ja |
nein |
2025-11-05 14:27:00 |
|
date/time log-message 1 as string |
| LOG1_MESSAGE_CODE |
585 |
1 |
ja |
nein |
5 |
|
log-message 1 code as number |
| LOG1_MESSAGE_TXT |
585 |
1 |
ja |
nein |
charging mode bulk |
|
log-message 1 as text |
| LOG1_MESSAGE_FULL_TXT |
582 |
3 |
ja |
nein |
2025-11-05 14:27:00 charging mode bulk (5) |
|
Fulltext LOG1 Message |
| LOG2_TIME |
586 |
3 |
ja |
nein |
2025-11-05 13:17:00 |
|
date/time log-message 2 as string |
| LOG2_MESSAGE_CODE |
589 |
1 |
ja |
nein |
8 |
|
log-message 2 code as number |
| LOG2_MESSAGE_TXT |
589 |
1 |
ja |
nein |
charging mode float |
|
log-message 2 as text |
| LOG2_MESSAGE_FULL_TXT |
586 |
3 |
ja |
nein |
2025-11-05 13:17:00 charging mode float (8) |
|
Fulltext LOG2 Message |
| LOG3_TIME |
590 |
3 |
ja |
nein |
2025-11-05 13:12:40 |
|
date/time log-message 3 as string |
| LOG3_MESSAGE_CODE |
593 |
1 |
ja |
nein |
6 |
|
log-message 3 code as number |
| LOG3_MESSAGE_TXT |
593 |
1 |
ja |
nein |
charging mode absorption |
|
log-message 3 as text |
| LOG3_MESSAGE_FULL_TXT |
590 |
3 |
ja |
nein |
2025-11-05 13:12:40 charging mode absorption (6) |
|
Fulltext LOG3 Message |
| LOG4_TIME |
594 |
3 |
ja |
nein |
2025-11-01 14:25:00 |
|
date/time log-message 4 as string |
| LOG4_MESSAGE_CODE |
597 |
1 |
ja |
nein |
5 |
|
log-message 4 code as number |
| LOG4_MESSAGE_TXT |
597 |
1 |
ja |
nein |
charging mode bulk |
|
log-message 4 as text |
| LOG4_MESSAGE_FULL_TXT |
594 |
3 |
ja |
nein |
2025-11-01 14:25:00 charging mode bulk (5) |
|
Fulltext LOG4 Message |
| LOG5_TIME |
598 |
3 |
ja |
nein |
2025-11-01 13:32:00 |
|
date/time log-message 5 as string |
| LOG5_MESSAGE_CODE |
601 |
1 |
ja |
nein |
8 |
|
log-message 5 code as number |
| LOG5_MESSAGE_TXT |
601 |
1 |
ja |
nein |
charging mode float |
|
log-message 5 as text |
| LOG5_MESSAGE_FULL_TXT |
598 |
3 |
ja |
nein |
2025-11-01 13:32:00 charging mode float (8) |
|
Fulltext LOG5 Message |
| LOG6_TIME |
602 |
3 |
ja |
nein |
2025-11-01 13:27:29 |
|
date/time log-message 6 as string |
| LOG6_MESSAGE_CODE |
605 |
1 |
ja |
nein |
6 |
|
log-message 6 code as number |
| LOG6_MESSAGE_TXT |
605 |
1 |
ja |
nein |
charging mode absorption |
|
log-message 6 as text |
| LOG6_MESSAGE_FULL_TXT |
602 |
3 |
ja |
nein |
2025-11-01 13:27:29 charging mode absorption (6) |
|
Fulltext LOG6 Message |
| LOG7_TIME |
606 |
3 |
ja |
nein |
2025-10-19 15:40:00 |
|
date/time log-message 7 as string |
| LOG7_MESSAGE_CODE |
609 |
1 |
ja |
nein |
5 |
|
log-message 7 code as number |
| LOG7_MESSAGE_TXT |
609 |
1 |
ja |
nein |
charging mode bulk |
|
log-message 7 as text |
| LOG7_MESSAGE_FULL_TXT |
606 |
3 |
ja |
nein |
2025-10-19 15:40:00 charging mode bulk (5) |
|
Fulltext LOG7 Message |
| LOG8_TIME |
610 |
3 |
ja |
nein |
2025-10-19 13:54:00 |
|
date/time log-message 8 as string |
| LOG8_MESSAGE_CODE |
613 |
1 |
ja |
nein |
8 |
|
log-message 8 code as number |
| LOG8_MESSAGE_TXT |
613 |
1 |
ja |
nein |
charging mode float |
|
log-message 8 as text |
| LOG8_MESSAGE_FULL_TXT |
610 |
3 |
ja |
nein |
2025-10-19 13:54:00 charging mode float (8) |
|
Fulltext LOG8 Message |
| LOG9_TIME |
614 |
3 |
ja |
nein |
2025-10-19 13:49:58 |
|
date/time log-message 9 as string |
| LOG9_MESSAGE_CODE |
617 |
1 |
ja |
nein |
6 |
|
log-message 9 code as number |
| LOG9_MESSAGE_TXT |
617 |
1 |
ja |
nein |
charging mode absorption |
|
log-message 9 as text |
| LOG9_MESSAGE_FULL_TXT |
614 |
3 |
ja |
nein |
2025-10-19 13:49:58 charging mode absorption (6) |
|
Fulltext LOG9 Message |
| LOG10_TIME |
618 |
3 |
ja |
nein |
2025-10-18 15:56:00 |
|
date/time log-message 10 as string |
| LOG10_MESSAGE_CODE |
621 |
1 |
ja |
nein |
5 |
|
log-message 10 code as number |
| LOG10_MESSAGE_TXT |
621 |
1 |
ja |
nein |
charging mode bulk |
|
log-message 10 as text |
| LOG10_MESSAGE_FULL_TXT |
618 |
3 |
ja |
nein |
2025-10-18 15:56:00 charging mode bulk (5) |
|
Fulltext LOG10 Message |
| GPS_SIGNAL_STATE |
622 |
1 |
ja |
nein |
- |
|
GPS signal state |
| GPS_VALID_TYPE |
622 |
1 |
ja |
nein |
- |
|
GPS valid type |
| GPS_NUM_SATTELITES1 |
623 |
1 |
ja |
nein |
0 |
|
Count of GPS sattelites |
| GPS_NUM_SATTELITES2 |
623 |
1 |
ja |
nein |
GPRMC (GPS USA) |
|
Type of last received packet |
| OUT1_STATE |
624 |
1 |
ja |
nein |
0 |
|
Output1 state |
| OUT1_STATE_TXT |
624 |
1 |
ja |
nein |
LOW |
|
Output1 state Low, High or PWM xxx |
| OUT2_STATE |
624 |
1 |
ja |
nein |
1 |
|
Output2 state |
| OUT2_STATE_TXT |
624 |
1 |
ja |
nein |
HIGH |
|
Output2 state Low, High or PWM xxx |
| OUT3_STATE |
625 |
1 |
ja |
nein |
1 |
|
Output3 state |
| OUT3_STATE_TXT |
625 |
1 |
ja |
nein |
HIGH |
|
Output3 state Low, High or PWM xxx |
| OUT4_STATE |
625 |
1 |
ja |
nein |
1 |
|
Output4 state |
| OUT4_STATE_TXT |
625 |
1 |
ja |
nein |
HIGH |
|
Output4 state Low, High or PWM xxx |
| GPS_RECEIVING_STRENGTH |
636 |
1 |
ja |
nein |
0 |
|
GPS receiving strength |
| GPS_ERROR_RTATE |
636 |
1 |
ja |
nein |
0 |
|
GPS error rate |
| I_BATT_IN_INTERNAL |
637 |
2 |
ja |
nein |
0 |
A |
Batterie Ladestrom ungeglättet ohne externe Sensoren |
| SOC |
639 |
1 |
ja |
nein |
72 |
% |
calculated SOC |
| ERROR_ISOMETER_ALARM |
641 |
1 |
ja |
nein |
0 |
|
0=no insulation error; 1=warnung insulation error |
| ERROR_ISOMETER_SHUTOFF |
641 |
1 |
ja |
nein |
0 |
|
0=no insulation error; 1=insulation error shutoff active |